Search found 59 matches

by John Reimer
Tue Feb 21, 2017 5:22 am
Forum: Viena
Topic: Edited Instruments Splits in Viena, now all samples are broken
Replies: 82
Views: 108157

Re: Edited Instruments Splits in Viena, now all samples are broken

Kenneth,
Here is the debug printout:
https://dl.dropboxusercontent.com/u/673 ... 0.996C.txt

However, the fault does not seem to have occurred this time.
I intend to keep using 0.996C and shall report if the fault reappears.

John Reimer
by John Reimer
Sun Feb 19, 2017 1:15 am
Forum: Viena
Topic: Edited Instruments Splits in Viena, now all samples are broken
Replies: 82
Views: 108157

Re: Edited Instruments Splits in Viena, now all samples are broken

Kenneth, I have to report that Viena 0.995 is corrupting samples, and the sound is similar to what has been happening with recent versions. It happens after purging some unused samples (actually samples that have been replaced by doing reassigns), and then saving. The corruption does not occur until...
by John Reimer
Fri Feb 03, 2017 7:52 pm
Forum: Viena
Topic: Edited Instruments Splits in Viena, now all samples are broken
Replies: 82
Views: 108157

Re: Edited Instruments Splits in Viena, now all samples are broken

Kenneth, I have been using the 0.995J and it is behaving itself nicely. However, I have noticed one odd thing when deleting splits. I very occasionally need to delete a whole range of splits. With older versions which allowed me to do this, once a split was deleted, it would highlight the “next in l...
by John Reimer
Wed Jan 25, 2017 10:20 am
Forum: Viena
Topic: Edited Instruments Splits in Viena, now all samples are broken
Replies: 82
Views: 108157

Re: Edited Instruments Splits in Viena, now all samples are broken

Kenneth, 0.995I is not showing the strange behaviour of the blue highlight on the Instrument name immediately slipping down to “Global”. HOWEVER, if I then right-click the name with the intention of doing a rename, Rename is greyed out. So it is not possible to rename an Instrument. And I still have...
by John Reimer
Wed Jan 25, 2017 1:41 am
Forum: Viena
Topic: Edited Instruments Splits in Viena, now all samples are broken
Replies: 82
Views: 108157

Re: Edited Instruments Splits in Viena, now all samples are broken

Kenneth, Regarding the split, having watched your video, that is exactly what I do, except that the new split does not display (or at least, it didn't yesterday). I haven't tried it today, because I've just got home from having a colonoscopy....... But I got a good report. I could get the split to d...
by John Reimer
Mon Jan 23, 2017 8:16 pm
Forum: Viena
Topic: Edited Instruments Splits in Viena, now all samples are broken
Replies: 82
Views: 108157

Re: Edited Instruments Splits in Viena, now all samples are broken

Kenneth, Two small bugs I noticed yesterday when working with 0.995G - 1. When adding a split, even after saving the addition, it will not display the new split until I have clicked on the global view of an ALTERNATIVE instrument and then returned to the one I am working on. (I discovered this worka...
by John Reimer
Thu Jan 19, 2017 10:20 am
Forum: Viena
Topic: Edited Instruments Splits in Viena, now all samples are broken
Replies: 82
Views: 108157

Re: Edited Instruments Splits in Viena, now all samples are broken

Kenneth, I have tried 0.995F, and it is certainly enabling me to delete splits in situations where the previous recent versions were failing. I have now embarked on making what will be (for me) a major soundfont, which I expect to take quite a number of weeks, and I shall use 0.995F exclusively, and...
by John Reimer
Thu Jan 19, 2017 1:25 am
Forum: Viena
Topic: Edited Instruments Splits in Viena, now all samples are broken
Replies: 82
Views: 108157

Re: Edited Instruments Splits in Viena, now all samples are broken

Kenneth,

For what it's worth, I've just had the 0.994 successfully remove a split. So I'm afraid that my reports are not consistent. I can add that the soundfonts involved (including the 0.995E test) are all new and very small.

John Reimer
by John Reimer
Tue Jan 17, 2017 7:49 pm
Forum: Viena
Topic: Edited Instruments Splits in Viena, now all samples are broken
Replies: 82
Views: 108157

Re: Edited Instruments Splits in Viena, now all samples are broken

Kenneth, It seems that we are not looking at the same thing. I click on the split I select to delete, then I click on Edit. Delete appears near the top of the list, but with 0.995D (and with 0.994, from memory) it usually appears greyed out, but very occasionally it is not greyed out. I never have t...